|
Name | ID | Default? | Description | Status | Type | Modified | Mod. by | Total Payloads | Distinct Payloads |
---|---|---|---|---|---|---|---|---|---|
alignment_proc12stage1_part14_noHemiCon | 1793 | ✘ | Test of new alignment for part14 of proc12 stage1 NOT using hemisphere constraints for L55 |
TESTING | DEV | 06/17/2021 9:42 a.m. | bilkat | 2 | 2 |
alignment_proc12stage1part14_lxtest1 | 1799 | ✘ | Test two-body decays |
TESTING | DEV | 06/19/2021 7:02 a.m. | bilkat | 2 | 2 |
alignment_proc12stage1_part14_sag | 1800 | ✘ | proc12 part14 stage1 with wire sagging |
TESTING | DEV | 06/19/2021 8:14 p.m. | bilkat | 2 | 2 |
alignment_proc12stage1_part14_sag2 | 1801 | ✘ | proc12 part14 stage1 with wire sagging - v2, sag up t L20 |
TESTING | DEV | 06/20/2021 1:20 a.m. | bilkat | 2 | 2 |
alignment_reset_MC | 2810 | ✘ | Reset alignment payloads for VXD and CDC to exactly zeros for default ideal MC simulation |
TESTING | DEV | 12/14/2022 12:42 p.m. | bilkat | 2 | 2 |
alignment_s-proc2_test1_stage2 | 1969 | ✘ | Realigned bucket25 as test for s-proc2 - stage2 |
TESTING | DEV | 08/27/2021 12:50 p.m. | bilkat | 240 | 6 |
alignment_s-proc2_test2_stage2 | 1970 | ✘ | Bucket25 test for s-proc2 stage2 full baseline 1M per block |
TESTING | DEV | 08/27/2021 2 p.m. | bilkat | 24 | 6 |
user_bilkat_testWrongMagneticFieldAlignReco_nominalAligned | 3200 | ✘ | Investigations of charge-momentum asymmetry. Default nominal MC alignment with correct B field |
TESTING | DEV | 02/15/2024 1 p.m. | bilkat | 6 | 6 |
alignment_online_new2021c | 2079 | ✘ | New baseline alignment for online GT and 2021c data. Created as average alignment in stage1 from s-proc2 |
TESTING | DEV | 10/21/2021 1:46 p.m. | bilkat | 2 | 2 |
staging_online_bilkat_20211021-152505 | 2080 | ✘ | needed for reasonable online performance |
OPEN | DEV | 10/21/2021 3:26 p.m. | bilkat | 2 | 2 |
user_bilkat_testWrongMagneticFieldAlignReco_1.5TAligned | 3201 | ✘ | Investigations of charge-momentum asymmetry. Default MC simulation with (wrong) 1.5T constant field used for reco and alignment. |
TESTING | DEV | 02/15/2024 1:02 p.m. | bilkat | 6 | 6 |
alignment_bucket19_fix | 2123 | ✘ | Bucket15 alignment is recalculated again on top of data_reprocessing_prompt which show issues with this bucket - see #BIIPERF-175 |
TESTING | DEV | 11/18/2021 8:34 p.m. | bilkat | 6 | 6 |
alignment_bucket19_fix_BeamSpot | 2124 | ✘ | Recalculated BeamSpot for Bucket15 alignment, which is recalculated again on top of data_reprocessing_prompt which show issues with this bucket - see #BIIPERF-175 |
TESTING | DEV | 11/18/2021 10:17 p.m. | bilkat | 135 | 1 |
user_bilkat_alignment_exp28_v1 | 3063 | ✘ | VXD+CDC alignment from B=0T cosmic data - preliminary, iteration 2 |
TESTING | DEV | 09/23/2023 10:34 p.m. | bilkat | 4 | 4 |
user_bilkat_testalignment_e30r2276to2343 | 3244 | ✘ | testing for timedep - first constant prompt stage |
TESTING | DEV | 03/25/2024 11:41 p.m. | bilkat | 6 | 6 |
user_bilkat_alignment_pxd_mask_v1 | 3064 | ✘ | PXD masking from Maiko from runs up to 45, exp 28 |
TESTING | DEV | 09/24/2023 8:19 p.m. | bilkat | 33 | 3 |
user_bilkat_alignment_prompt2proc_scale_0.3 | 3141 | ✘ | This is a rescaled alignment_misalignment_prompt_to_proc12stage1_v4 misalignment (VXD sensors only) by factor 0.3 |
TESTING | DEV | 12/14/2023 1:53 p.m. | bilkat | 2 | 2 |
user_bilkat_testWrongMagneticFieldAlignReco_nominalAlignedWithJpsi | 3204 | ✘ | Same as user_bilkat_testWrongMagneticFieldAlignReco_nominalAligned, but also mass-constrained J/psi used for alignment - 50k B0 -> J/psi KS |
TESTING | DEV | 02/16/2024 1:57 p.m. | bilkat | 6 | 6 |
user_bilkat_alignment_prompt2proc_scale_0.5 | 3142 | ✘ | This is a rescaled alignment_misalignment_prompt_to_proc12stage1_v4 misalignment (VXD sensors only) by factor 0.5 |
TESTING | DEV | 12/14/2023 1:53 p.m. | bilkat | 2 | 2 |
user_bilkat_testWrongMagneticFieldAlignReco_nominalAligned_noWires_IPfixed | 3205 | ✘ | Same as user_bilkat_testWrongMagneticFieldAlignReco_nominalAligned but with fixed wires (and IP) |
TESTING | DEV | 02/16/2024 1:57 p.m. | bilkat | 6 | 6 |
user_bilkat_testWrongMagneticFieldAlignReco_nominalAligned_noWires_IPfree | 3206 | ✘ | Same as user_bilkat_testWrongMagneticFieldAlignReco_nominalAligned but with fixed wires and floating IP |
TESTING | DEV | 02/16/2024 1:57 p.m. | bilkat | 6 | 6 |
user_bilkat_testVXDBowingEvery10s | 3247 | ✘ | Special-named payload containing extracted residual changes upsampled to 10s |
TESTING | DEV | 03/29/2024 5:01 p.m. | bilkat | 15 | 8 |
user_bilkat_alignment_exp29_average | 3160 | ✘ | Average alignment from runs 7 to 1508, using average from exp28 as starting point, CDC not realigned (yet here) |
TESTING | DEV | 01/11/2024 3:03 p.m. | bilkat | 6 | 6 |
user_bilkat_alignment_exp28_v2 | 3069 | ✘ | Alignment for exp28 with all PXD sensors ON, CO2 temp=-30deg |
TESTING | DEV | 09/27/2023 4:43 p.m. | bilkat | 6 | 6 |
user_bilkat_testWrongMagneticField_nominalAlignedWithJpsiTight | 3210 | ✘ | As user_bilkat_testWrongMagneticField_nominalAligned. but using very tight width for júpsi mass in alignment |
TESTING | DEV | 02/19/2024 1:21 p.m. | bilkat | 6 | 6 |